Real-time Guiding Catheter and Guidewire Detection for Congenital Cardiovascular Interventions

Ma, YingLiang and Alhrishy, Mazen and Panayiotou, Maria and Ananth Narayan, Srivinas and Fazili, Ansab and Mountney, Peter and Rhode, Kawal (2017) Real-time Guiding Catheter and Guidewire Detection for Congenital Cardiovascular Interventions. In: Proceedings - Functional Imaging and Modeling of the Heart. FIMH, pp. 172-182.

[img]
Preview
Text
FIMH2017_GuideWireDet_Revised_CameraReady_BCU.pdf

Download (745kB)

Abstract

Guiding catheters and guidewires are used extensively in pediatric cardiac catheterization procedures for congenital heart diseases (CHD). Detecting their positions in fluoroscopic X-ray images is important for several clinical applications, such as visibility enhancement for low dose X-ray images, and co-registration between 2D and 3D imaging modalities. As guiding catheters are made from thin plastic tubes, they can be deformed by cardiac and breathing motions. Therefore, detection is the essential step before automatic tracking of guiding catheters in live X-ray fluoroscopic images. However, there are several wire-like artifacts existing in X-ray images, which makes developing a real-time robust detection method very challenging. To solve those challenges in real-time, a localized machine learning algorithm is built to distinguish between guiding catheters and artifacts. As the machine learning algorithm is only applied to potential wire-like objects, which are obtained from vessel enhancement filters, the detection method is fast enough to be used in real-time applications. The other challenge is the low contrast between guiding catheters and background, as the majority of X-ray images are low dose. Therefore, the guiding catheter might be detected as a discontinuous curve object, such as a few disconnected line blocks from the vessel enhancement filter. A minimum energy method is developed to trace the whole wire object. Finally, the proposed methods are tested on 1102 images which are from 8 image sequences acquired from 3 clinical cases. Results show an accuracy of 0.87 ± 0.53 mm which is measured as the error distances between the detected object and the manually annotated object. The success rate of detection is 83.4%.

Item Type: Book Section
Identification Number: https://doi.org/10.1007/978-3-319-59448-4_17
Dates:
DateEvent
2017Published
Subjects: CAH02 - subjects allied to medicine > CAH02-05 - medical sciences > CAH02-05-01 - medical technology
Divisions: Faculty of Computing, Engineering and the Built Environment
Faculty of Computing, Engineering and the Built Environment > School of Computing and Digital Technology
Depositing User: Ian Mcdonald
Date Deposited: 04 Jul 2017 11:37
Last Modified: 22 Mar 2023 12:01
URI: https://www.open-access.bcu.ac.uk/id/eprint/4797

Actions (login required)

View Item View Item

Research

In this section...